Nr. 0.405 GB
Oct. 2001, Sfb (4-) Sq 4
Latest update Aug. 2011
|
 |
|
Primer for Alfix PlaneMix levelling compounds
For preparation of different types of substrates prior to levelling. Adjusts surface absorbency and improves adhesion for subsequent levelling or other finish.
• For indoor and outdoor use
• Adheres to most surfaces
• High water resistance
• Low emission
|
|
| Coverage |
| Substrate |
Mixing ratio |
Coverage undiluted primer litres/m² |
| Concrete, screed, levelling compound |
1 part primer to 3 part water |
0.06 |
| Concrete or levelling compound, outdoors |
1 part primer to 6 parts water |
0.05 |
| Wooden substrates |
undiluted |
0.20 |
| Existing tiles, terrazzo, vinyl, paint/lacquer |
1 part primer to 2 parts levelling powder |
0.15 |
|
|
| Packaging |
|
Available in 2,5 litres and 10 litres plastic containers.
|
|
| Surface preparation |
|
The surface should be dimensionally stable, sound, and clean. Free from laitance, grease, and dust. There should be no blooms or crack formations. Residues from grease or soap can be removed with Alfix Deep Cleaner. Ensure that paint work is sound and not flaking. Rough-sand/matt smooth or dense surfaces.
|
|
| Application |
|
For absorbent surfaces, such as concrete, dilute Alfix PlaneMixPrimer with clean water in the ratio 1:3. For smooth or dense substrates, wash/brush the surface using a mixture of Alfix PlaneMix Primer and levelling powder in the ratio 1:2.
Outdoors: prime with Alfix PlaneMixPrimer diluted 1:6 with water.
Apply Alfix Primer to the surface with use of broom, brush, or roller and work it well into the surface leaving no visible puddles.
Allow primer to dry before commencing further treatment.
Ensure a room temperature of min. +10°C.
Min. drying time at +20°C: 1 hour.
Should levelling imply several layers, priming before each new application is required.
For very absorbent surfaces, extra priming may be required.
|
|
| Cleaning |
|
Clean residues from tools with water before the primer sets. Once dried, primer can be removed mechanically or with solvent.
Wear protective gloves during work since the product tends to stick strongly to the skin.
|
|
| Test |
|
Low emission, GEV-EMICODE EC1 - test defined by the German institute Gemeinschaft Emissionskontrollierte Verlegestoffe.
|
|
| Technical enquiries |
|
Levelling compounds - plane, smooth surfaces with Alfix
Wet rooms – Tanking with Alfix
Product info on:
• Alfix Deep Cleaner
• Alfix PlaneMix
Product health and safety data /COSH
For further information, please consult our Technical Services Dept.
|
|
| Technical data |
| Working temperature |
Min +10°C |
| Density |
1.0 kg/litre |
| Drying time |
1 hour at +20°C |
| Shelf life |
Min. 12 months in unopened container. Keep protected from frost. |
|
|
|
| |