Contact
 Safety datasheet
Produktinfo
   
 
Feb. 2011, Sfb (4-) Sq 4.
Latest update Sep. 2011
 
 
CE-Classifikation, Tile Grouts  PDF printfil
EN standard 13888
 
Alfix tile grouts have the following classifications:

How to read a classification:

C or R:
C = cement-based product
R = epoxy product

Requirements of CG 1:
Flexural tensile strength after 28 days of dry storage as well as after frost and thaw:
≥3,5 N/mm²
Compressive strength after 28 days of dry storage as well as after frost and thaw:
≥15 N/mm²
Water absorption after 30 minutes: ≤5 g
Water absorption after 240 minutes: ≤10 g
Linear shrinkage: ≤2 mm/m
Abrasion resistance: ≤2000mm³

Requirements of CG 2:
Flexural tensile strength after 28 days of dry storage as well as after frost and thaw:
≥3,5 N/mm²
Compressive strength after 28 days of dry storage as well as after frost and thaw:
≥15 N/mm²
Water absorption after 30 minutes: ≤2 g
Water absorption after 240 minutes: ≤5 g
Linear shrinkage: ≤2 mm/m
Abrasion resistance: ≤1000mm³

Requirements of RG:
Flexural tensile strength after 28 days of dry storage:
≥30 N/mm²
Compressive strength after 28 days of dry storage:
≥45 N/mm²
Water absorption after 240 minutes: ≤0,1 g
Linear shrinkage: ≤1,5 mm/m
Abrasion resistance: ≤250mm³

 

Product  
CE-Classification
 Cerafill 5    CG 1
 Cerafill 5 colour   CG 2
 Cerafill 10    CG 1
 Cerafill 10 colour CG 2 
 Cerafill 15 quick    CG 2
 Cerafill 18 resistant CG 2
 Cerafill 20    CG 1
 C2 Epoxy    RG 2